{"id":45,"date":"2021-01-20T22:21:22","date_gmt":"2021-01-20T22:21:22","guid":{"rendered":"https:\/\/www.protecfire.de\/?page_id=45"},"modified":"2024-10-10T14:30:57","modified_gmt":"2024-10-10T14:30:57","slug":"brandschutzloesungen-fuer-windkraftanlagen","status":"publish","type":"page","link":"https:\/\/www.protecfire.de\/es\/brandschutzloesungen-fuer-windkraftanlagen\/","title":{"rendered":"Turbinas e\u00f3licas"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"45\" class=\"elementor elementor-45\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b93e489 elementor-section-height-min-height elementor-section-content-middle elementor-section-boxed elementor-section-height-default elementor-section-items-middle\" data-id=\"b93e489\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-bd0c5b4\" data-id=\"bd0c5b4\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9495d72 elementor-widget elementor-widget-text-editor\" data-id=\"9495d72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>\u00a1DONDE NADIE LLEGA!<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-273a18c elementor-widget elementor-widget-heading\" data-id=\"273a18c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Sistemas de extinci\u00f3n de incendios para aerogeneradores<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5443593 elementor-widget elementor-widget-image\" data-id=\"5443593\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"754\" height=\"201\" src=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2026\/01\/VdS-logo-2026.svg\" class=\"attachment-large size-large wp-image-13306\" alt=\"vds fire suppression - protecci\u00f3n contra incendios VdS\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-8499abc\" data-id=\"8499abc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6f07fc9 elementor-widget elementor-widget-image\" data-id=\"6f07fc9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/protecfire.de\/wind-turbines-fire-suppression\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"83\" height=\"27\" src=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2023\/01\/firespywind-blue.svg\" class=\"attachment-large size-large wp-image-11463\" alt=\"Feuerl\u00f6schanlagen f\u00fcr f\u00fcr Windkraftanlagen\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-93c9b2e elementor-section-content-middle elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"93c9b2e\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-f1efd89\" data-id=\"f1efd89\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2eb0ac9 elementor-widget elementor-widget-image\" data-id=\"2eb0ac9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"214\" height=\"215\" src=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/icon-sector-wind@10x.webp\" class=\"attachment-full size-full wp-image-9727\" alt=\"sistema de protecci\u00f3n contra incendios de los aerogeneradores\" srcset=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/icon-sector-wind@10x.webp 214w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/icon-sector-wind@10x-150x150.webp 150w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/icon-sector-wind@10x-12x12.webp 12w\" sizes=\"(max-width: 214px) 100vw, 214px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-473bf93\" data-id=\"473bf93\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5d21d46 elementor-widget elementor-widget-heading\" data-id=\"5d21d46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">SISTEMAS DE EXTINCI\u00d3N DE INCENDIOS PARA TURBINAS E\u00d3LICAS<\/h3>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-33e0fa4 elementor-section-content-top elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"33e0fa4\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-ed1e299\" data-id=\"ed1e299\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f0dcd4a elementor-widget elementor-widget-text-editor\" data-id=\"f0dcd4a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<blockquote><p><b>\"Las operaciones se interrumpieron durante aproximadamente 150 d\u00edas; la p\u00e9rdida total ascendi\u00f3 a unos 2 millones de euros\".<\/b><\/p><\/blockquote>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2f8d8f elementor-widget elementor-widget-text-editor\" data-id=\"a2f8d8f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Su protecci\u00f3n, su beneficio.<\/strong><\/p><ul><li>Protecci\u00f3n contra la p\u00e9rdida total de los aerogeneradores<\/li><li>Tiempos de inactividad m\u00e1s cortos<\/li><li>Mayor aceptaci\u00f3n de los inversores<\/li><li>Aseguramiento de los aerogeneradores<\/li><li>Primas de seguro m\u00e1s favorables<\/li><li>Evitar da\u00f1os en la imagen<\/li><li>Condiciones de construcci\u00f3n, por ejemplo, en zonas boscosas<\/li><li>Protecci\u00f3n del medio ambiente<\/li><li>Componentes esenciales del sistema en las turbinas e\u00f3licas<\/li><li>Contenedor de agente extintor con unidad de control interna<\/li><li>Elementos de accionamiento neum\u00e1tico<\/li><li>Boquillas de pulverizaci\u00f3n fina<\/li><li>V\u00e1lvulas de control<\/li><li>Dise\u00f1o del concepto de extinci\u00f3n<\/li><\/ul><div>\u00a0<\/div><p class=\" translation-block\">En el dise\u00f1o del concepto de extinci\u00f3n, la atenci\u00f3n no se centra en la protecci\u00f3n de la g\u00f3ndola como \u00e1rea, sino en la <strong>protecci\u00f3n de objetos individuales<\/strong>. En los aerogeneradores, hay que proteger los siguientes puntos cr\u00edticos:<\/p><ul><li>Armarios de control<\/li><li>Transformadores<\/li><li>Generadores<\/li><li>Frenos y embragues<\/li><li>Sistema hidr\u00e1ulico<\/li><\/ul><p>De este modo, los incendios pueden detectarse de forma r\u00e1pida y eficaz, de modo que se evita la propagaci\u00f3n del foco del incendio en la fase inicial.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-51dd53e elementor-widget elementor-widget-image\" data-id=\"51dd53e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"754\" height=\"201\" src=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2026\/01\/VdS-logo-2026.svg\" class=\"attachment-large size-large wp-image-13306\" alt=\"vds fire suppression - protecci\u00f3n contra incendios VdS\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba88f5f elementor-widget elementor-widget-heading\" data-id=\"ba88f5f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Nuestra protecci\u00f3n contra incendios Fine Spray est\u00e1 certificada para proteger:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d4b776b elementor-widget elementor-widget-text-editor\" data-id=\"d4b776b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><b>Sala\/Instalaci\u00f3n aerogenerador<\/b><\/p><ul><li>G\u00f3ndola con generador, transformador, sistemas hidr\u00e1ulicos, caja de cambios, freno, accionamiento del azimut<\/li><li>Cubo con accionamiento de paso y generador, si procede<\/li><li>Suelos elevados con sumidero de aceite e instalaciones el\u00e9ctricas y de cables<\/li><li>Subestaci\u00f3n el\u00e9ctrica central, salas de conmutaci\u00f3n (sin transformador)<\/li><li>Base\/plataforma de la torre con instalaciones disponibles, si procede<\/li><\/ul><p><b>Protecci\u00f3n de la instalaci\u00f3n, por ejemplo,<\/b><\/p><ul><li>Control, inversor, armarios de distribuci\u00f3n (BT\/MT), cerrados<\/li><li>Transformador<\/li><li>Control, inversor, armarios de distribuci\u00f3n (BT\/MT), abiertos<\/li><li>Sistema hidr\u00e1ulico, abierto<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0412435 elementor-widget__width-auto e-transform elementor-widget elementor-widget-button\" data-id=\"0412435\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_transform_scale_effect_hover&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:1.05,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_hover_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_hover_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/shop.vds.de\/download\/vds-3523en\/cf367c31-20a3-497e-88e3-cc5c9221d936\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-download\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M216 0h80c13.3 0 24 10.7 24 24v168h87.7c17.8 0 26.7 21.5 14.1 34.1L269.7 378.3c-7.5 7.5-19.8 7.5-27.3 0L90.1 226.1c-12.6-12.6-3.7-34.1 14.1-34.1H192V24c0-13.3 10.7-24 24-24zm296 376v112c0 13.3-10.7 24-24 24H24c-13.3 0-24-10.7-24-24V376c0-13.3 10.7-24 24-24h146.7l49 49c20.1 20.1 52.5 20.1 72.6 0l49-49H488c13.3 0 24 10.7 24 24zm-124 88c0-11-9-20-20-20s-20 9-20 20 9 20 20 20 20-9 20-20zm64 0c0-11-9-20-20-20s-20 9-20 20 9 20 20 20 20-9 20-20z\"><\/path><\/svg>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Documento de VdS sobre protecci\u00f3n contra incendios en aerogeneradores<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-4055f60\" data-id=\"4055f60\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9f64c1b elementor-widget elementor-widget-text-editor\" data-id=\"9f64c1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><b>Funcionamiento y operaci\u00f3n de un sistema de extinci\u00f3n por aspersi\u00f3n fina<\/b><\/p><p>El sistema de extinci\u00f3n se activar\u00e1 autom\u00e1ticamente mediante un disparador neum\u00e1tico en caso de un aumento cr\u00edtico de la temperatura (por ejemplo, 30\u00b0 por encima de la temperatura m\u00e1xima de funcionamiento prevista). Nuestro sistema de lucha contra incendios es un sistema de extinci\u00f3n por pulverizaci\u00f3n fina que utiliza boquillas especiales para rociar el agente extintor en forma de niebla fina.<\/p><p>El tama\u00f1o de las gotas seleccionado es lo suficientemente grande como para garantizar que las gotas tengan suficiente energ\u00eda cin\u00e9tica para llegar al foco del incendio. Esto es especialmente importante en los aerogeneradores, ya que puede haber flujos de aire en la g\u00f3ndola que lo impidan.<br \/>La enorme superficie de reacci\u00f3n de las gotas de niebla en relaci\u00f3n con la cantidad de agente extintor hace que el fuego se vea r\u00e1pidamente privado de gran parte de su energ\u00eda. Por lo tanto, el nivel de temperatura desciende r\u00e1pidamente, impidiendo la reignici\u00f3n. El efecto de enfriamiento interrumpe las condiciones de reacci\u00f3n t\u00e9rmica en el foco del incendio, reduciendo as\u00ed la velocidad de reacci\u00f3n para que el fuego se extinga.<\/p><p>Adem\u00e1s del efecto de enfriamiento, la tecnolog\u00eda de pulverizaci\u00f3n fina tambi\u00e9n tiene un efecto de asfixia, como ocurre con la extinci\u00f3n de incendios por niebla de agua fina.<\/p><p>Para intensificar los efectos de extinci\u00f3n descritos, el agente extintor contiene un aditivo formador de espuma. El objetivo es conseguir una mayor adherencia y, por tanto, un mayor \u00e9xito en la extinci\u00f3n de los materiales en llamas. Esta mezcla desempe\u00f1a un papel crucial en la eficacia del sistema para riesgos espec\u00edficos en zonas donde hay l\u00edquidos combustibles.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-8efc364 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8efc364\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-46dd732\" data-id=\"46dd732\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-fc6de26 elementor-widget elementor-widget-heading\" data-id=\"fc6de26\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ventajas de la propiedad:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38b53b0 elementor-widget elementor-widget-text-editor\" data-id=\"38b53b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Aprobado por VdS&nbsp;<\/li><li>Sin Presi\u00f3n<\/li>\n<li>Sin Electricidad<\/li>\n<li class=\" translation-block\">(casi) <strong>sin mantenimiento<\/strong><\/li>\n<li>Detecci\u00f3n y extinci\u00f3n ultrarr\u00e1pidas<\/li>\n<li>Sistema h\u00edbrido (l\u00edquido\/gas)<\/li>\n<li>Funciona en todos los \u00e1ngulos y posiciones<\/li>\n<li class=\" translation-block\"><strong>Sin falsas alarmas<\/strong> - gracias al detector patentado<\/li>\n<li class=\" translation-block\"><strong>Sistema robusto<\/strong> (temperatura de -30\u00bac a 80\u00bac)<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-696728a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"696728a\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4a12833\" data-id=\"4a12833\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9bdf40f elementor-widget elementor-widget-heading\" data-id=\"9bdf40f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">SISTEMAS DE EXTINCI\u00d3N DE INCENDIOS PARA TURBINAS E\u00d3LICAS:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-478af2b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"478af2b\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-ed0b091\" data-id=\"ed0b091\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-0d6100c elementor-section-height-min-height elementor-section-boxed elementor-section-height-default\" data-id=\"0d6100c\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-ce0e265\" data-id=\"ce0e265\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e5b9144 elementor-widget elementor-widget-text-editor\" data-id=\"e5b9144\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ir para producto<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90bd357 e-transform elementor-widget elementor-widget-image\" data-id=\"90bd357\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_transform_scale_effect_hover&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:1.05,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_hover_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_hover_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/protecfire.de\/wind-turbines-fire-suppression\/\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"665\" height=\"223\" src=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2021\/01\/firespy-wind@8x.png\" class=\"attachment-large size-large wp-image-581\" alt=\"Firespy - Sistemas autom\u00e1ticos de extinci\u00f3n de incendios\" srcset=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2021\/01\/firespy-wind@8x.png 665w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2021\/01\/firespy-wind@8x-300x101.png 300w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2021\/01\/firespy-wind@8x-16x5.png 16w\" sizes=\"(max-width: 665px) 100vw, 665px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-b0fb9b8\" data-id=\"b0fb9b8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f91f23b e-transform elementor-widget elementor-widget-image\" data-id=\"f91f23b\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_transform_scale_effect&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:1.05,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/protecfire.de\/wind-turbines-fire-suppression\/\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1751\" height=\"674\" src=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/11\/firespy-wind-containers.352.webp\" class=\"attachment-full size-full wp-image-10491\" alt=\"sistemas de extinci\u00f3n de incendios en turbinas e\u00f3licas Vds Approved\" srcset=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/11\/firespy-wind-containers.352.webp 1751w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/11\/firespy-wind-containers.352-300x115.webp 300w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/11\/firespy-wind-containers.352-1024x394.webp 1024w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/11\/firespy-wind-containers.352-768x296.webp 768w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/11\/firespy-wind-containers.352-1536x591.webp 1536w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/11\/firespy-wind-containers.352-18x7.webp 18w\" sizes=\"(max-width: 1751px) 100vw, 1751px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bf2188 elementor-widget elementor-widget-text-editor\" data-id=\"0bf2188\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Desarrollado con los principales fabricantes de aerogeneradores, Firespy es un sistema probado y fiable.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-2e3f5f7\" data-id=\"2e3f5f7\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-20b4a72 elementor-section-height-min-height elementor-section-boxed elementor-section-height-default\" data-id=\"20b4a72\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-2811404\" data-id=\"2811404\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ea7bd1c elementor-widget elementor-widget-text-editor\" data-id=\"ea7bd1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ir para producto<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6e7a6c e-transform elementor-widget elementor-widget-image\" data-id=\"a6e7a6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_transform_scale_effect_hover&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:1.05,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_hover_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_hover_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/protecfire.de\/detexline-electric\/\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"272\" src=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2021\/03\/detexline-electric@8x.png\" class=\"attachment-large size-large wp-image-2125\" alt=\"detexline el\u00e9ctrico\" srcset=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2021\/03\/detexline-electric@8x.png 919w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2021\/03\/detexline-electric@8x-300x102.png 300w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2021\/03\/detexline-electric@8x-768x262.png 768w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2021\/03\/detexline-electric@8x-16x5.png 16w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-a9ff9bc\" data-id=\"a9ff9bc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2158bc5 e-transform elementor-widget elementor-widget-image\" data-id=\"2158bc5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_transform_scale_effect&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:1.05,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;_transform_scale_effect_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/protecfire.de\/detexline-electric\/\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"207\" src=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/protecfire-detexline-electric-tank.257-1024x265.webp\" class=\"attachment-large size-large wp-image-9282\" alt=\"protecci\u00f3n contra incendios en armarios el\u00e9ctricos\" srcset=\"https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/protecfire-detexline-electric-tank.257-1024x265.webp 1024w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/protecfire-detexline-electric-tank.257-300x78.webp 300w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/protecfire-detexline-electric-tank.257-768x199.webp 768w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/protecfire-detexline-electric-tank.257-1536x398.webp 1536w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/protecfire-detexline-electric-tank.257-18x5.webp 18w, https:\/\/www.protecfire.de\/wp-content\/uploads\/2022\/09\/protecfire-detexline-electric-tank.257.webp 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33f28b7 elementor-widget elementor-widget-text-editor\" data-id=\"33f28b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Proteger m\u00e1s de un compartimento con el mismo dep\u00f3sito con v\u00e1lvulas direccionales.<\/strong><br \/><strong>Armarios el\u00e9ctricos | Autobuses de hidr\u00f3geno y el\u00e9ctricos |Turbinas e\u00f3licas<\/strong><span>otros<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>WHERE NO ONE ELSE REACHES! Fire Suppression Systems for Wind Turbines FIRE SUPPRESSION SYSTEMS FOR WIND TURBINES &#8220;Operations were interrupted for approximately 150 days; the total loss amounted to approximately EUR 2 million.&#8221; Your protection, your gain! Protection against total loss of the wind turbines Shorter downtimes Greater acceptance from investors Insurability of the wind [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-45","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Automatic Fire Suppression Systems for Wind Turbines | Electric Cabinets<\/title>\n<meta name=\"description\" content=\"Fire Suppression Systems for Off- and Inshore Wind Turbines - No Pressure, No Electricity, No Maintenance, No False Alarms - Made In Germany!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.protecfire.de\/es\/brandschutzloesungen-fuer-windkraftanlagen\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Automatic Fire Suppression Systems for Wind Turbines | Electric Cabinets\" \/>\n<meta property=\"og:description\" content=\"Fire Suppression Systems for Off- and Inshore Wind Turbines - No Pressure, No Electricity, No Maintenance, No False Alarms - Made In Germany!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.protecfire.de\/es\/brandschutzloesungen-fuer-windkraftanlagen\/\" \/>\n<meta property=\"og:site_name\" content=\"protecfire\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/protecfire.de\" \/>\n<meta property=\"article:modified_time\" content=\"2024-10-10T14:30:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/protecfire.de\/wp-content\/uploads\/2026\/01\/VdS-logo-2026.svg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@protecfire1\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/brandschutzloesungen-fuer-windkraftanlagen\\\/\",\"url\":\"https:\\\/\\\/www.protecfire.de\\\/brandschutzloesungen-fuer-windkraftanlagen\\\/\",\"name\":\"Automatic Fire Suppression Systems for Wind Turbines | Electric Cabinets\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/sv\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/brandschutzloesungen-fuer-windkraftanlagen\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/brandschutzloesungen-fuer-windkraftanlagen\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/protecfire.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/VdS-logo-2026.svg\",\"datePublished\":\"2021-01-20T22:21:22+00:00\",\"dateModified\":\"2024-10-10T14:30:57+00:00\",\"description\":\"Fire Suppression Systems for Off- and Inshore Wind Turbines - No Pressure, No Electricity, No Maintenance, No False Alarms - Made In Germany!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/brandschutzloesungen-fuer-windkraftanlagen\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.protecfire.de\\\/brandschutzloesungen-fuer-windkraftanlagen\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/brandschutzloesungen-fuer-windkraftanlagen\\\/#primaryimage\",\"url\":\"https:\\\/\\\/protecfire.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/VdS-logo-2026.svg\",\"contentUrl\":\"https:\\\/\\\/protecfire.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/VdS-logo-2026.svg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/brandschutzloesungen-fuer-windkraftanlagen\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.protecfire.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wind Turbines\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/sv\\\/#website\",\"url\":\"https:\\\/\\\/www.protecfire.de\\\/sv\\\/\",\"name\":\"protecfire\",\"description\":\"Automatic Fire Suppression Systems\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/sv\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.protecfire.de\\\/sv\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/sv\\\/#organization\",\"name\":\"protecfire\",\"url\":\"https:\\\/\\\/www.protecfire.de\\\/sv\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/sv\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.protecfire.de\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/protecfire-logo-original-1920x462-1.svg\",\"contentUrl\":\"https:\\\/\\\/www.protecfire.de\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/protecfire-logo-original-1920x462-1.svg\",\"width\":1920,\"height\":462,\"caption\":\"protecfire\"},\"image\":{\"@id\":\"https:\\\/\\\/www.protecfire.de\\\/sv\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/protecfire.de\",\"https:\\\/\\\/x.com\\\/protecfire1\",\"https:\\\/\\\/www.instagram.com\\\/protecfire.de\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/protecfire-gmbh\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCPNT-TI0OtsFsXkjCp2sKvg\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sistemas autom\u00e1ticos de extinci\u00f3n de incendios para aerogeneradores | Cuadros el\u00e9ctricos","description":"Sistemas de extinci\u00f3n de incendios para aerogeneradores marinos y costeros - Sin presi\u00f3n, sin electricidad, sin mantenimiento, sin falsas alarmas - \u00a1Fabricado en Alemania!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.protecfire.de\/es\/brandschutzloesungen-fuer-windkraftanlagen\/","og_locale":"es_ES","og_type":"article","og_title":"Automatic Fire Suppression Systems for Wind Turbines | Electric Cabinets","og_description":"Fire Suppression Systems for Off- and Inshore Wind Turbines - No Pressure, No Electricity, No Maintenance, No False Alarms - Made In Germany!","og_url":"https:\/\/www.protecfire.de\/es\/brandschutzloesungen-fuer-windkraftanlagen\/","og_site_name":"protecfire","article_publisher":"https:\/\/www.facebook.com\/protecfire.de","article_modified_time":"2024-10-10T14:30:57+00:00","og_image":[{"url":"https:\/\/protecfire.de\/wp-content\/uploads\/2026\/01\/VdS-logo-2026.svg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_site":"@protecfire1","twitter_misc":{"Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.protecfire.de\/brandschutzloesungen-fuer-windkraftanlagen\/","url":"https:\/\/www.protecfire.de\/brandschutzloesungen-fuer-windkraftanlagen\/","name":"Sistemas autom\u00e1ticos de extinci\u00f3n de incendios para aerogeneradores | Cuadros el\u00e9ctricos","isPartOf":{"@id":"https:\/\/www.protecfire.de\/sv\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.protecfire.de\/brandschutzloesungen-fuer-windkraftanlagen\/#primaryimage"},"image":{"@id":"https:\/\/www.protecfire.de\/brandschutzloesungen-fuer-windkraftanlagen\/#primaryimage"},"thumbnailUrl":"https:\/\/protecfire.de\/wp-content\/uploads\/2026\/01\/VdS-logo-2026.svg","datePublished":"2021-01-20T22:21:22+00:00","dateModified":"2024-10-10T14:30:57+00:00","description":"Sistemas de extinci\u00f3n de incendios para aerogeneradores marinos y costeros - Sin presi\u00f3n, sin electricidad, sin mantenimiento, sin falsas alarmas - \u00a1Fabricado en Alemania!","breadcrumb":{"@id":"https:\/\/www.protecfire.de\/brandschutzloesungen-fuer-windkraftanlagen\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.protecfire.de\/brandschutzloesungen-fuer-windkraftanlagen\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.protecfire.de\/brandschutzloesungen-fuer-windkraftanlagen\/#primaryimage","url":"https:\/\/protecfire.de\/wp-content\/uploads\/2026\/01\/VdS-logo-2026.svg","contentUrl":"https:\/\/protecfire.de\/wp-content\/uploads\/2026\/01\/VdS-logo-2026.svg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.protecfire.de\/brandschutzloesungen-fuer-windkraftanlagen\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.protecfire.de\/"},{"@type":"ListItem","position":2,"name":"Wind Turbines"}]},{"@type":"WebSite","@id":"https:\/\/www.protecfire.de\/sv\/#website","url":"https:\/\/www.protecfire.de\/sv\/","name":"protecfire","description":"Sistemas autom\u00e1ticos de extinci\u00f3n de incendios","publisher":{"@id":"https:\/\/www.protecfire.de\/sv\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.protecfire.de\/sv\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.protecfire.de\/sv\/#organization","name":"protecfire","url":"https:\/\/www.protecfire.de\/sv\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.protecfire.de\/sv\/#\/schema\/logo\/image\/","url":"https:\/\/www.protecfire.de\/wp-content\/uploads\/2023\/01\/protecfire-logo-original-1920x462-1.svg","contentUrl":"https:\/\/www.protecfire.de\/wp-content\/uploads\/2023\/01\/protecfire-logo-original-1920x462-1.svg","width":1920,"height":462,"caption":"protecfire"},"image":{"@id":"https:\/\/www.protecfire.de\/sv\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/protecfire.de","https:\/\/x.com\/protecfire1","https:\/\/www.instagram.com\/protecfire.de\/","https:\/\/www.linkedin.com\/company\/protecfire-gmbh\/","https:\/\/www.youtube.com\/channel\/UCPNT-TI0OtsFsXkjCp2sKvg"]}]}},"_links":{"self":[{"href":"https:\/\/www.protecfire.de\/es\/wp-json\/wp\/v2\/pages\/45","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.protecfire.de\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.protecfire.de\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.protecfire.de\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.protecfire.de\/es\/wp-json\/wp\/v2\/comments?post=45"}],"version-history":[{"count":131,"href":"https:\/\/www.protecfire.de\/es\/wp-json\/wp\/v2\/pages\/45\/revisions"}],"predecessor-version":[{"id":20542,"href":"https:\/\/www.protecfire.de\/es\/wp-json\/wp\/v2\/pages\/45\/revisions\/20542"}],"wp:attachment":[{"href":"https:\/\/www.protecfire.de\/es\/wp-json\/wp\/v2\/media?parent=45"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}